HENGFENGYOU ELECTRIC --SMART ELECTRIC GLOBAL SERVICE PROVIDER
   

Low Voltage Power Cable

WDZ-YJ(F)E23 Low Voltage Power Cable

  • Brand: HENGFENGYOU
  • Series: WDZ-YJ(F)E23
  • USES: Power Transmission
  • Country of origin: China
  • Terms of payment: L/C, T/T, Western Union, Paypal, Money Gram
  • Certification: ISO9001、CE

WDZ-YJ(F)E23 Low Voltage Power Cable Global Procurement Guide
Radiation crosslinked polyethylene insulated polyolefin sheathed low smoke halogen-free flame retardant power cable (armored) with rated voltage of 0.6/1kv
Product introduction
Scope of application
This product is applicable to AC 50Hz transmission and distribution lines with rated voltage of 0.6/1kv.
Executive standard
Gb/t 12706-2008 extruded insulated power cables and accessories with rated voltages from 1kV to 35kV
Gb/t19666-2005 general rules for flame retardant and fire resistant wires and cables
Model and specification
Model: wdz (a, B, C, d) -yj (f) e63
Name: copper core irradiation crosslinked polyethylene insulated non-magnetic steel tape armored polyolefin sheathed low smoke halogen-free flame retardant power cable
Nominal sectional area mm ²: 16-300 (1 core)
Model: wdz (a, B, C, d) -yjl (f) e63
Name: aluminum core irradiated XLPE insulated non-magnetic steel tape armored polyolefin sheathed low smoke halogen-free flame retardant power cable
Nominal sectional area mm ²: 16-300 (1 core)
Model: wdz (a, B, C, d) -yj (f) E23
Name: copper core irradiated XLPE insulated steel tape armored polyolefin sheathed low smoke halogen-free flame retardant power cable
Nominal sectional area mm ²: 1.5-300 (2-5 cores)
Model: wdz (a, B, C, d) -yjl (f) E23
Name: aluminum core irradiated XLPE insulated steel tape armored polyolefin sheathed low smoke halogen-free flame retardant power cable
Nominal sectional area mm ²: 1.5-300 (2-5 cores)
Model: wdz (a, B, C, d) n-yj (f) e63
Name: copper core irradiation crosslinked polyethylene insulated non-magnetic steel tape armored polyolefin sheathed low smoke halogen-free flame retardant fire-resistant power cable
Nominal sectional area mm ²: 16-300 (1 core)
Model: wdz (a, B, C, d) n-yj (f) E23
Name: copper core irradiation crosslinked polyethylene insulated steel tape armored polyolefin sheathed low smoke halogen-free flame retardant fire-resistant power cable
Nominal sectional area mm ²: 1.5-300 (2-5 cores)
Guidelines for use
Rated voltage uo/u:0.6/1kv;
Long term allowable working temperature: the long-term working temperature of the conductor shall not exceed 90 ℃, and the maximum working temperature during short circuit shall not exceed 250 ℃ (the maximum duration shall not exceed 5S);
The cable laying temperature shall not be lower than 0 ℃;
Minimum bending radius (D is the outer diameter of the cable)
Single core cable: 20d;
Multi core cable: 15d.
Special characteristics
Low smoke halogen-free flame retardant products: flame retardant, halogen-free, low smoke characteristics meet the requirements of gb/t 19666-2005 general rules for flame retardant and fire resistant wires and cables;
Low smoke halogen-free flame retardant and fire-resistant products: flame retardant, fire-resistant, halogen-free and low smoke characteristics meet the requirements of gb/t 19666-2005 general rules for flame retardant and fire resistant wires and cables.

WDZ-YJ(F)E23 Low Voltage Power Cable FAQ
  1. What is the rated voltage of WDZ-YJ(F)E23 cable?
    The cable is designed for low voltage applications, typically rated at 0.6/1kV (600V to 1000V).

  2. What does "WDZ" in the cable model signify?
    "WDZ" indicates halogen-free (W), low-smoke (D), and flame-retardant (Z) properties, complying with environmental and safety standards.

  3. What is the operating temperature range of this cable?
    The standard operating temperature ranges from -20°C to +90°C, with a maximum short-circuit temperature of 250°C.

  4. Is this cable suitable for outdoor installation?
    Yes, it can be used outdoors, but additional mechanical protection (e.g., conduit) is recommended for direct burial or exposed environments.

  5. Does WDZ-YJ(F)E23 have UV resistance?
    The cable has basic UV resistance, but prolonged direct sunlight exposure may degrade insulation over time—consider shielded or armored versions for harsh conditions.

  6. What conductor materials are available?
    It uses copper (Cu) or tinned copper conductors, with options for solid or stranded configurations.

  7. Is the cable compliant with international standards?
    Yes, it meets IEC, GB, and other regional standards for halogen-free, flame-retardant, and low-smoke performance.

  8. Can this cable be used in fire-resistant applications?
    While flame-retardant, it is not inherently fire-resistant. For critical fire safety circuits, specify a fire-rated variant (e.g., WDZN-YJY).

  9. What is the bending radius during installation?
    The minimum bending radius is typically 10x the cable diameter for fixed installations and 15x for flexible applications.

  10. How should WDZ-YJ(F)E23 cables be stored before use?
    Store in a dry, cool place away from direct sunlight and chemicals. Avoid mechanical stress or sharp bends to prevent insulation damage.



News and information

Contact us

WhatsApp:

+86 15853252696(Jack)

+86 135 8926 2999(MARTIN)

Tel:+86-0532-68688801

Fax:+86-0532-87038801

Email: hfy@hengfengyou.com

Address: No.638,Zhongcheng Road, Chengyang District, Qingdao City,China

Leave a message now - get the latest industry insights, star products, and success stories of hengfengyou electric

Click to replace Click to replace

© 2021 Copyright By Hengfengyou Electric

xml map    |    Site map

whatsapp
(+86) 15853252696
WhatsApp Click Contact